New Items, Suggestions and Ideas with possible relevance to MDTs



1. A new Wire Tension Meter , proposed by Alexandr Volkov, JINR Dubna
Here is some information about it (wtm1.txt, wtm1.eps, wtm2.txt).
For more detailed information, please send email to: Alexandr Volkov

2. MDT "Negative High Voltage Treatment (NHVT)"
Shows promising results as a 'cure' against dark currents in ATLAS MDTs and noise reduction in TDC spectra during data taking with the BOS98 MPI prototype chamber at the CERN H8 testbeam;
U. Bratzler, H. Dietl, Jun-Sep 1999 (ATLAS Note in preparation.)
For more information, see these documents ( Test Facilities Meeting, 13 Sep.1999) or send email to Uwe Bratzler.

Further News, Work and Progress with NHVT:
2.1 The QC_QA Results of the BOS-Module-0 Monitored Drift Tubes, M. Dris, et al. (document, ATLAS Note).
2.2 Dark Current Testing of ATLAS Module 0 Drift Tubes, D. Levin (document, ATLAS Note)
2.3 MDT Dark Currents and NHVT - Some New Results and Overview of Situation, U. Bratzler (document).
2.4 Cracks in the End Plug, S. Kircher (document).