LTDB_002
- SOLVED: SCA_1 number readed (19768) don't correspond to expected one (32184) from data base
- Understood : db not up to date
LTDB_008
- Sca_5: MTx_4: I2C bus error , switch to degrated mode
LTDB_009
- the IDs for GBTx and GBT-SCA are not recorded by BNL
LTDB_013
- Sca_2: MTx_4: I2C bus error , switch to degrated mode
LTDB_014
- Sca_5: MTx_4: I2C bus error , switch to degrated mode
LTDB_015
- Sca_2: MTx_4: I2C bus error , switch to degrated mode
- Sca_3: Locx2_4: Register 1 : bit 2 stuck at 0 :taken into account in default value
LTDB_016
- Sca_1: MTx_3: Register 2: bit 1 stuck at 1 : taken into account in default value
LTDB_021
* Sca_4: MTx_4:
I2C bus error : switch to degrated mode
LTDB_023
* Sca_2: MTx_4:
I2C bus error : switch to degrated mode
* Sca_5: MTx_4:
I2C bus error : switch to degrated mode
LTDB_027
- Sca_3: MTx_1: Register 1: bit 5 stuck at 0 : Waiting BNL expert
LTDB_035
- Sca_5: MTx_4: I2C bus error : switch to degrated mode
LTDB_037
- Sca_5: MTx_4: I2C bus error , switch to degrated mode
- Sca_3: MTx_4: I2C bus error , switch to degrated mode
LTDB 041
- SOLVED: Since 22/01/20 (power cut recovery) Link #5 not responding
- 28/01 : Test with AUX/PRIM all SCA responding
- 07/02 : Test with a different FELIX : same issue
- => GBTx / MTRx issue ?
- => 11/02 GBTx reset => SOLVED
LTDB 091
- Sca_5: MTx_4: I2C bus error , switch to degrated mode
--
EtienneMarieFortin - 2019-11-13