MDT Guide for Experts
Useful phone numbers
Name |
Expertise |
CERN |
Other |
Agostino Lanza |
services, Power Supplies |
162294 |
Sergei Malyukov |
cabling |
164960 |
Wieslaw Iwanski |
DSS, power |
160997 |
Martin Jaekel |
US15 racks |
163197 |
Jianbei Liu |
MDT EC gas |
162532 |
Joerg Dubbert |
MDT gas |
72250 |
Thilo Pauly |
Trigger |
162242 |
David Berge |
Trigger |
164976 |
Henk Boterenbrood |
MROD |
165351 |
Stefan Schlenker |
DCS PS |
162187 |
Robert Hart |
DCS Initialization |
162116 |
Jay Chapman |
CSM |
72776 |
Yasuo Arai |
AMT |
71153 |
John Oliver |
ASD |
71152 |
Benedetto Gorini |
ROS |
72369 |
Gokhan Unel |
TDAQ |
71754 |
David Francis |
TDAQ |
160200 |
How to start an MDT standalone run
Two partitions are available for standalone runs with MDT detectors:
part_MDT and
part_MDT2.
The former is to be used for Barrel-only runs, while the latter is for Endcap-only runs. The current configuration
of the LTP modules requires a single TTC partition, either MDTEndcapA-TTC or MDTBarrelA-TTC, to act as a MasterTrigger
of the DAQ partition. Instructions for running an Endcap-only partition on a point1 machine:
muondaq@pc-atlas-cr-06> tcsh
muondaq@pc-atlas-cr-06> mdt2
muondaq@pc-atlas-cr-06> run
Common OKS operations
By-pass ROS and use TCP/IP data output
Two steps: change all Output fields of the RCD objects from EmulatedDataOut to TCPDataOut, then set the flag
OutputToROS in
MRODXParameters equal to false.
MDT Control Panel
The MDT Control Panel is a
java application installed in the ~muondaq account in point1.
It allows one to quickly check which chambers are included/excluded from the current MDT partition, and to add or remove
chambers from it. The MDT Control Panel is activated as follows:
muondaq@pc-atlas-cr-06> tcsh
muondaq@pc-atlas-cr-06> MdtControlPanel
The command
MdtControlPanel is a shorthand for:
muondaq@pc-atlas-cr-06> java -cp MdtControlPanel.jar MdtControlPanel
PS Mainframe Configuration
Whenever the configuration of DC/DC distributors in an EASY3000S crate is
changed, it is necessary to update the firmware of the Caen SY1527 Universal Multichannel
Power Supply System which manages the status of the MDT power supplies.
A new configuration file is to be produced with EASY Rack Builder, a Java application
available at
http://www.caen.it/nuclear/software_download.php.
Registration is needed in orfer to download software packages.
The new configuration file needs to be loaded in the mainframe
as follows:
muondaq@pc-atlas-cr-06> telnet 10.145.48.242 1527
Username: xxxxx
Password: xxxxx
Utility System Upgrade Download image via TFTP
Utiliy System Upgrade Upgrade Running image
Frequently Encountered Errors
- TTC timeout errors MDT-EC-TTC CS::TimeoutIssue Timeout on transition CONFIGURE
- Pattern generator for the LTP was at 2 Hz, but it can handle only one million patterns. As such LTP triggers with patterns can't go under 40 Hz.
- EB timeout errors MDT-EBController CS::TimeoutIssue Timeout on transition CONNECT
- Check that there aren't EB segments included in segments and resources that don't in fact exist!
- Check that the RCD data out is TCP and not emulated for EB running on pc-rpc-dcs-01
- Check if the EBInputMemoryPool memory page size is wrong or if ROS objects are off under segments and resources.
- Data taking stops with invalid name error RootController mrs::InvalidParameter Invalid name for parameter USER_ID
- In run parameter maximum number of events has been set to something. This number of events has been acquired
- CSM parity errors MDT-EC-RCD ROSException MROD-EC36-17 Input 2 EML1C09: 2 CSM link errors (Parity/LDOWN)14925 (sbc-mdt-rcc-ecc-03.cern.ch MDT-EC3-RCD MRODXModule-dev etc)
- Check chamber initialization
- CMEM BPA MDT-EBController CS::ControllerIssue Child MDT-EB-RCD is in error state ERROR 0x70e0704 => minor: Error 4 in package 7 => CMEM_RCC library: error from call to ioctl function => error 14 in package in 7 => CMEM RCC library: error in the driver in call to BPA function
- Change the EB segment: EBInputMemoryPool, change number of pages in page size
- Event counter stops upgrading after very few events, trigger rate zero
- Check that the number of includes in the partition file matches the actual number of included files
Supplementary Gas Monitoring Guide
The following webpage provides additional information about the gas system.
However, it is not available from the P1 internal network.
http://mpi.web.cern.ch/mpi/atlas_mdt_gas_system/instructions.html
--
AlbertoBelloni - 14 Feb 2008