The events in the denominator are required to have one (two) MC electron(s) with |eta|<2.5 and pt>5GeV and reconstructed by offline for Wgamma(Zgamma).
Wgamma
The study was made with privately produced sample (Et(gamma)>10GeV).
Trigger condition |
L1 & HLT efficiency (%) |
1e isolated |
67.5 (0.7) |
1e relaxed |
68.0 (0.7) |
Zgamma
The study was made with official CSA07 sample.
Trigger condition |
L1 & HLT efficiency (%) |
1e isolated |
88.3 (0.4) |
1e relaxed |
88.6 (0.4) |
2e isolated |
68.2 (0.3) |
2e relaxed |
75.7 (0.4) |
1g isolated |
39.9 (0.2) |
1g relaxed |
25.1 (0.2) |
1e isolated OR 2e isolated |
91.0 (0.4) |
1e isolated OR 2e relaxed |
92.7 (0.4) |
1e relaxed OR 2e isolated |
92.3 (0.4) |
1e relaxed OR 2e relaxed |
92.5 (0.4) |
--
ChiaMingKuo - 07 Jul 2008